ACI 318-19 Changes to the Concrete Design Standard
Post-Tensioned
Post-Tensioned
Back to course
[Please upgrade your browser to play this video content]
Video Transcription
Video Summary
The transcript discusses updates to the ACI 318-19 code concerning post-tensioning, focusing on relocated provisions for clarity, particularly on post-tension slab foundations on expansive soil for residential construction. Changes include reinforcing crack control requirements for unbonded tendons and detailing standards in Chapter 25 to prevent bearing failures at anchor zones. Additionally, Chapter 26 clarifies formwork design requirements, emphasizing the need for contractors to accommodate movement during post-tensioning, which affects slab and beam deformation. The revisions aim to enhance clarity, safety, and consistency in post-tensioning structural practices.
Keywords
ACI 318-19
post-tensioning
expansive soil
crack control
formwork design
×